T11 series decoration
hot electric puppet
T11 series of the description of the hot electric puppet
Armoric resistance probe part is a mineral insulation
cable , which is usually called armor
cable . This
cable contains a stainless steel shell Essence The internal conductor is placed in insulating and compressed in a highly compact ceramic module.
The sheets outside are composed of stainless steel or nickel alloys (precious metal thermocouple, may be platinum or platinum alloy) material.
The internal wires and thermocouple shells
measurement position end welding together. In terms of design, the measurement of sensitive elements is not insulated with the protective cover, and it is also welded on the thermal puppet. The connection wire is connected to the other end of the armor cable. The electrical connection interface is mainly completed through the wiring, and these wires are connected through the cable connection or wiring block.
T11 series of thermocouple Application
Suitable for all industrial and laboratory applications
Functional features
Application at a temperature range of 0 ℃-+1200 ℃
Stainless steel shelter, mineral insulation cable
High mechanical strength, shockproof
Essential safety type (ATex)
Because the flexibility and diameter of the rod can be done very small because the flexibility and diameter of the rod can be used in thermal heat of the armor, so it can be used in places that are not easy to approach.
The essential safety model design is suitable for dangerous areas. This series of resistance thermometers have a "essential safety type" explosion -proof test certificate 94/9/EC (ATEX). Compliance with the EN50020 manufacturer's statement also provides simultaneously.
T11 series of the hot electric puppet model
From 850 ° C to 950 ° C, the K -type thermocouple has a dangerous area. If it works for a long time in the above range, we recommend N -type sensors.
The application range of these thermometers should not only exceed the maximum temperature mentioned above, but also cannot exceed the maximum temperature that the sheet material can withstand.
The in thermometer custard can be made into a dual -branch thermometer at 203mm. The thermocouple puppet is insulating at the measurement point, unless it is specified separately.
T11 series decorated
thermocouple sensor The allowable error
The cold -end temperature of 0 ° C is the benchmark value that allows errors to allow errors before the thermometer window.
Press rod
This series of Kai installed probes can be used in an environment of up to 1200 ° C.
Rod material
■ Nickel alloy 2.4816 (Inconel 600)
Up to 1200 ° C (air)
The standard material exposed to high temperature requires peculiar corrosion resistance, anti -severe pressure
Crack corrosion and chlorine melt corrosion point, as well as ammonia water at any concentration and temperature
corrosion. Anti -halogen, chlorine gas, and chlorine hydrogenation corrosion.
■ Stainless steel
850C (air)
Water vapor and flue gas in the chemical industry are well corrosion.
Diameter of the rod
0.5mm,
1.0mm,
1.5mm,
3.0mm,
4.5mm,
6.0mm or
8.0mm (with installation tube),
Please ask separately