J -shaped glass fiber insulation flat flat -thermocouple cable/wire (IEC)| General explanation | A good temperature range, but it does not prevent the liquid from entering. Quite flexible, but it cannot provide good mechanical protection. |
|---|---|
| Cable length | 10m、25m、50m、100m |
| Cable type | Flat twisted line |
| Core/stock line | 1/0.2mm、1/0.315mm、7/0.2mm |
| Conduct cross section 1/0.2 (mm2) | 0.032 |
| Conduct cross section 1/0.315 (MM2) | 0.078 |
| Conduct cross section 7/0.2 (mm2) | 0.219 |
| Exterior color | Black, white |
| + Color | Black |
| - Color | White |
| Discharge line | Do not |
| Insulation Materials | Glass fiber insulation |
| Route resistance 1/0.2 (Ohm per combination rice) | 19.3 |
| Circuit resistance 1/0.315 (Om per combination rice) | 7.8 |
| Route resistance 7/0.2 (ohm/group rice) | 2.7 |
| Maximum. temperature | +350 °C (as high as 400 ° C in a short time) |
| The smallest. temperature | -60°C |
| + Conductor | iron |
| -Dorpad | Constanttan |
| Screen | No |
| Meet the standard | Color code (core wire and protective cover) that conforms to IEC-584-3 |
| Thermocouple type | j |
| Tolerance | Level 2 |